882IS Plus Intrinsically Safe Digital Weight Indicator

882IS Plus Intrinsically Safe Digital Weight Indicator

  • Contact Now for Immediate Pricing
  • 1(800)-268-3269
  • inquiry@interweigh.ca

RiceLake 882IS Plus Intrinsically Safe Digital Weight Indicator

  • 0.8in, seven-digit, seven-segment LCD display with white LED backlight
  • Stainless steel IP66 enclosure
  • T4 temperature rating
  • Battery life display icon
  • Excitation for four 350 ohm or eight 700 ohm load cells
  • Tilt stand
  • Numeric keypad (882IS Plus only)
  • Duplex fiber optic interface
  • Power ON/OFF; battery save mode
  • Configurable local/remote mode
  • I/O module option: one serial port, optional analog output, optional Fieldbus cards, Ethernet TCP/IP
  • Time & date (requires I/O module)
  • Setpoint functionality with remote indicator

Specifications 

Load Cell Excitation:
3.0 VDC at 87.5 ohm, 4.6 VDC at 700 ohm

Load Cell Current:
34 mA (4 × 350 ohm load cells) or (8 × 700 ohm load cells)

Load Cell Cabling:
Four and six-wire with remote sensing (recommended)

Analog Signal Input Range:
0.6 mV/V to 4.0 mV/V

Analog Signal Sensitivity:
0.2 μV/graduation minimum
1.5 μV/graduation recommended

Conversion Rate:
60 updates/second

Resolution:
10,000 displayed graduations (NTEP Certified),
1,000,000 expanded
The maximum number of allowed graduations will vary by application

Display Increments:
1, 2, 5

Display:
Seven-digit, seven-segment LCD display 121 × 24 dot
matrix messaging area with white LED backlight

Decimal Point:
Configurable with dead zeros

Unit Switching:
Configurable for two units of measurement with front panel operation with conversion for tare and setpoint values

Front Panel Control Switches:
882IS: 
Zero, Gross/Net, Tare, Print, Units Conv, Start, Stop
882IS Plus: Zero, Gross/Net, Tare, Print, Units Conv, Start, Stop, Full numeric keypad

Front Panel:
Ten-button plus power button flat membrane panel

Front Panel Annunciators:
Center Zero, Gross, Net, Motion, lb, kg, oz, g

Motion Band:
Configurable to ± 1 or ± 3 graduations, 1-second delay (or Off)

Power Input:
5.8 to 7.9 VDC, 100 to 175 mA
Maximum power consumption 0.25 watts

Operating Temperature:
14 °F to 104 °F (-10 °C to 40 °C) legal

Electrical Operating Temperature:
14 °F to 104 °F (-10 °C to 40 °C) legal

Rating/Material:
IP66 enclosure
Stainless steel

Optional Battery:
Operating times: 4 × 350 ohm = 60 hrs.
1 × 350 ohm = 80 to 100 hrs. Charging times: 8 to 10 hrs

Weight:
6.1 lb (2.8 kg)

Warranty:
One-year limited

Intrinsic Safety:
FM/cFM
Class I,II,III, Division 1, Groups ABCDEFG T4
Class I, Zone 0 AEx/Ex ia IIC T4 Ga
Zone 20 AEx/Ex ia IIIC T135°C Da
Ta = -10 °C to 40 °C (14 °F to 104 °F)
ATEX/IECEx
II 1 G Ex ia IIC T4 Ga
II 1 D Ex ia IIIC T135°C Da

Approvals:
UL/cUL Listed*
FM Entity
ATEX
IECEx
NTEP CC 19-015
Measurement Canada
OIML R76/2006-A-NL1-21.11
EU Legal for Trade T11166
*UL is only applicable to 882IS I/O and battery charger

RiceLake 882IS Plus Intrinsically Safe Digital Weight Indicator

  • 0.8in, seven-digit, seven-segment LCD display with white LED backlight
  • Stainless steel IP66 enclosure
  • T4 temperature rating
  • Battery life display icon
  • Excitation for four 350 ohm or eight 700 ohm load cells
  • Tilt stand
  • Numeric keypad (882IS Plus only)
  • Duplex fiber optic interface
  • Power ON/OFF; battery save mode
  • Configurable local/remote mode
  • I/O module option: one serial port, optional analog output, optional Fieldbus cards, Ethernet TCP/IP
  • Time & date (requires I/O module)
  • Setpoint functionality with remote indicator

Specifications 

Load Cell Excitation:
3.0 VDC at 87.5 ohm, 4.6 VDC at 700 ohm

Load Cell Current:
34 mA (4 × 350 ohm load cells) or (8 × 700 ohm load cells)

Load Cell Cabling:
Four and six-wire with remote sensing (recommended)

Analog Signal Input Range:
0.6 mV/V to 4.0 mV/V

Analog Signal Sensitivity:
0.2 μV/graduation minimum
1.5 μV/graduation recommended

Conversion Rate:
60 updates/second

Resolution:
10,000 displayed graduations (NTEP Certified),
1,000,000 expanded
The maximum number of allowed graduations will vary by application

Display Increments:
1, 2, 5

Display:
Seven-digit, seven-segment LCD display 121 × 24 dot
matrix messaging area with white LED backlight

Decimal Point:
Configurable with dead zeros

Unit Switching:
Configurable for two units of measurement with front panel operation with conversion for tare and setpoint values

Front Panel Control Switches:
882IS: 
Zero, Gross/Net, Tare, Print, Units Conv, Start, Stop
882IS Plus: Zero, Gross/Net, Tare, Print, Units Conv, Start, Stop, Full numeric keypad

Front Panel:
Ten-button plus power button flat membrane panel

Front Panel Annunciators:
Center Zero, Gross, Net, Motion, lb, kg, oz, g

Motion Band:
Configurable to ± 1 or ± 3 graduations, 1-second delay (or Off)

Power Input:
5.8 to 7.9 VDC, 100 to 175 mA
Maximum power consumption 0.25 watts

Operating Temperature:
14 °F to 104 °F (-10 °C to 40 °C) legal

Electrical Operating Temperature:
14 °F to 104 °F (-10 °C to 40 °C) legal

Rating/Material:
IP66 enclosure
Stainless steel

Optional Battery:
Operating times: 4 × 350 ohm = 60 hrs.
1 × 350 ohm = 80 to 100 hrs. Charging times: 8 to 10 hrs

Weight:
6.1 lb (2.8 kg)

Warranty:
One-year limited

Intrinsic Safety:
FM/cFM
Class I,II,III, Division 1, Groups ABCDEFG T4
Class I, Zone 0 AEx/Ex ia IIC T4 Ga
Zone 20 AEx/Ex ia IIIC T135°C Da
Ta = -10 °C to 40 °C (14 °F to 104 °F)
ATEX/IECEx
II 1 G Ex ia IIC T4 Ga
II 1 D Ex ia IIIC T135°C Da

Approvals:
UL/cUL Listed*
FM Entity
ATEX
IECEx
NTEP CC 19-015
Measurement Canada
OIML R76/2006-A-NL1-21.11
EU Legal for Trade T11166
*UL is only applicable to 882IS I/O and battery charger

More from Chemical
Intrinsically Safe Portable Drum Scale
Interweigh
Lift-Deck Quick Clean Weighing Systems
Interweigh
Low Profile Floor Scales
Interweigh
1280 Enterprise Series
Rice Lake
882IS Plus Intrinsically Safe Digital Weight Indicator
Rice Lake
680HE Synergy Series Hostile Environment Digital Weight Indicator
Rice Lake
Recently viewed