RiceLake 882IS Plus Intrinsically Safe Digital Weight Indicator

  • 0.8in, seven-digit, seven-segment LCD display with white LED backlight
  • Stainless steel IP66 enclosure
  • T4 temperature rating
  • Battery life display icon
  • Excitation for four 350 ohm or eight 700 ohm load cells
  • Tilt stand
  • Numeric keypad (882IS Plus only)
  • Duplex fiber optic interface
  • Power ON/OFF; battery save mode
  • Configurable local/remote mode
  • I/O module option: one serial port, optional analog output, optional Fieldbus cards, Ethernet TCP/IP
  • Time & date (requires I/O module)
  • Setpoint functionality with remote indicator

Specifications 

Load Cell Excitation:
3.0 VDC at 87.5 ohm, 4.6 VDC at 700 ohm

Load Cell Current:
34 mA (4 × 350 ohm load cells) or (8 × 700 ohm load cells)

Load Cell Cabling:
Four and six-wire with remote sensing (recommended)

Analog Signal Input Range:
0.6 mV/V to 4.0 mV/V

Analog Signal Sensitivity:
0.2 μV/graduation minimum
1.5 μV/graduation recommended

Conversion Rate:
60 updates/second

Resolution:
10,000 displayed graduations (NTEP Certified),
1,000,000 expanded
The maximum number of allowed graduations will vary by application

Display Increments:
1, 2, 5

Display:
Seven-digit, seven-segment LCD display 121 × 24 dot
matrix messaging area with white LED backlight

Decimal Point:
Configurable with dead zeros

Unit Switching:
Configurable for two units of measurement with front panel operation with conversion for tare and setpoint values

Front Panel Control Switches:
882IS: 
Zero, Gross/Net, Tare, Print, Units Conv, Start, Stop
882IS Plus: Zero, Gross/Net, Tare, Print, Units Conv, Start, Stop, Full numeric keypad

Front Panel:
Ten-button plus power button flat membrane panel

Front Panel Annunciators:
Center Zero, Gross, Net, Motion, lb, kg, oz, g

Motion Band:
Configurable to ± 1 or ± 3 graduations, 1-second delay (or Off)

Power Input:
5.8 to 7.9 VDC, 100 to 175 mA
Maximum power consumption 0.25 watts

Operating Temperature:
14 °F to 104 °F (-10 °C to 40 °C) legal

Electrical Operating Temperature:
14 °F to 104 °F (-10 °C to 40 °C) legal

Rating/Material:
IP66 enclosure
Stainless steel

Optional Battery:
Operating times: 4 × 350 ohm = 60 hrs.
1 × 350 ohm = 80 to 100 hrs. Charging times: 8 to 10 hrs

Weight:
6.1 lb (2.8 kg)

Warranty:
One-year limited

Intrinsic Safety:
FM/cFM
Class I,II,III, Division 1, Groups ABCDEFG T4
Class I, Zone 0 AEx/Ex ia IIC T4 Ga
Zone 20 AEx/Ex ia IIIC T135°C Da
Ta = -10 °C to 40 °C (14 °F to 104 °F)
ATEX/IECEx
II 1 G Ex ia IIC T4 Ga
II 1 D Ex ia IIIC T135°C Da

Approvals:
UL/cUL Listed*
FM Entity
ATEX
IECEx
NTEP CC 19-015
Measurement Canada
OIML R76/2006-A-NL1-21.11
EU Legal for Trade T11166
*UL is only applicable to 882IS I/O and battery charger

RiceLake 882IS Plus Intrinsically Safe Digital Weight Indicator

  • 0.8in, seven-digit, seven-segment LCD display with white LED backlight
  • Stainless steel IP66 enclosure
  • T4 temperature rating
  • Battery life display icon
  • Excitation for four 350 ohm or eight 700 ohm load cells
  • Tilt stand
  • Numeric keypad (882IS Plus only)
  • Duplex fiber optic interface
  • Power ON/OFF; battery save mode
  • Configurable local/remote mode
  • I/O module option: one serial port, optional analog output, optional Fieldbus cards, Ethernet TCP/IP
  • Time & date (requires I/O module)
  • Setpoint functionality with remote indicator

Specifications 

Load Cell Excitation:
3.0 VDC at 87.5 ohm, 4.6 VDC at 700 ohm

Load Cell Current:
34 mA (4 × 350 ohm load cells) or (8 × 700 ohm load cells)

Load Cell Cabling:
Four and six-wire with remote sensing (recommended)

Analog Signal Input Range:
0.6 mV/V to 4.0 mV/V

Analog Signal Sensitivity:
0.2 μV/graduation minimum
1.5 μV/graduation recommended

Conversion Rate:
60 updates/second

Resolution:
10,000 displayed graduations (NTEP Certified),
1,000,000 expanded
The maximum number of allowed graduations will vary by application

Display Increments:
1, 2, 5

Display:
Seven-digit, seven-segment LCD display 121 × 24 dot
matrix messaging area with white LED backlight

Decimal Point:
Configurable with dead zeros

Unit Switching:
Configurable for two units of measurement with front panel operation with conversion for tare and setpoint values

Front Panel Control Switches:
882IS: 
Zero, Gross/Net, Tare, Print, Units Conv, Start, Stop
882IS Plus: Zero, Gross/Net, Tare, Print, Units Conv, Start, Stop, Full numeric keypad

Front Panel:
Ten-button plus power button flat membrane panel

Front Panel Annunciators:
Center Zero, Gross, Net, Motion, lb, kg, oz, g

Motion Band:
Configurable to ± 1 or ± 3 graduations, 1-second delay (or Off)

Power Input:
5.8 to 7.9 VDC, 100 to 175 mA
Maximum power consumption 0.25 watts

Operating Temperature:
14 °F to 104 °F (-10 °C to 40 °C) legal

Electrical Operating Temperature:
14 °F to 104 °F (-10 °C to 40 °C) legal

Rating/Material:
IP66 enclosure
Stainless steel

Optional Battery:
Operating times: 4 × 350 ohm = 60 hrs.
1 × 350 ohm = 80 to 100 hrs. Charging times: 8 to 10 hrs

Weight:
6.1 lb (2.8 kg)

Warranty:
One-year limited

Intrinsic Safety:
FM/cFM
Class I,II,III, Division 1, Groups ABCDEFG T4
Class I, Zone 0 AEx/Ex ia IIC T4 Ga
Zone 20 AEx/Ex ia IIIC T135°C Da
Ta = -10 °C to 40 °C (14 °F to 104 °F)
ATEX/IECEx
II 1 G Ex ia IIC T4 Ga
II 1 D Ex ia IIIC T135°C Da

Approvals:
UL/cUL Listed*
FM Entity
ATEX
IECEx
NTEP CC 19-015
Measurement Canada
OIML R76/2006-A-NL1-21.11
EU Legal for Trade T11166
*UL is only applicable to 882IS I/O and battery charger