Accuracy: ± (0.1% +1 d) of applied load
Resolution: 2,000 to 3,750 d standard (Up to 10,000 d available)
Enclosure: NEMA Type 4, IP65, powder coated cast aluminum
Lifting Eye & Hook: Crosby® or equivalent with 360° non-bearing swivel hook
Design Overload: 200% Safe / 500% Ultimate
Functions: Power: Turns unit ON or OFF Zero: Zeros applied load up to 100% of capacity (limited range in NTEP/OIML configurations) Tare: Tares applied load and displays weight in Net mode User: Programmable as test, units, net/gross, total, peak hold and setpoints
|
Display: 5-digit, 1.5 in (38 mm) LED with programmable brightness control
Displayable Units: Pounds or kilogram selectable
Annunciators: COZ, Net, Gross, Total, Peak, Low Battery, lb/kg, Motion, Setpoints, ACK IN, ACK OUT, RF
Power: 6 Volt rechargeable battery. 115/230 VAC battery charger is included
Operating Time: Up to 80 hours between charging with typical use. Less with optional RF Model
Operating Temperature: 14 °F to 104 °F (-10 °C to 40 °C) Legal for Trade: 14 °F to 104 °F (-10 °C to 40 °C)
Auto-Off Mode: Select for 15, 30, 45, 60 minutes or Off
|
Auto Sleep Mode: Power down during non-use and power up with weight change or any key press
Service Counters: Counts number of lifts over percentage of capacity and lifts over capacity
Calibration: Digital
Filtering: OFF, LO, HI-1, HI-2 selectable
Warranty: One-year limited
|